Server Technology C2XG36TE-DQME2966/C Switched POPS Expansion Pro2 PDU - 36x Configurable Alt Phase HDOT Outlets - 208v - 3-phase - 60a

Factory Sealed 3 Left
• Brand new
• Original manufacturer packaging
• Full manufacturer warranty

Now only:
$1,874.97



General
Model Number

PRO2

Product Name

Server Technology PRO2 Expansion PDU

Product Type

PDU

Features
HDOT Cx Outlets

Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.

Hot-Swap Network Card

Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.

Temperature/Humidity Monitoring

Supports two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.

Auto-Flip Current Display

Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high density cabinets.

Per-Outlet Power Sensing

POPS (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.

Branch Circuit Protection

This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic hydraulic circuit breakers or UL 248 fuses.

Alternating-Phase Outlets

Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.

High Temperature Rating

This product has been tested and approved for safe and reliable operation in 60 C data center environments.

Color-Coded Options

Select from six colors to designate PDU circuits in the data center black, white, red, green, blue, and yellow.

Network Monitoring

Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Star Multi-Linking

PRO2 provides the ability to link up to four power circuits using one IP address.

IP Access, Security & Communications

Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.

Per-Inlet Power Sensing

PIPS (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.

Branch Current Monitoring

Monitors current at each breaker branch and provides SNMP based alerts and emails on high usage that risks a tripped circuit.

Outlet Control

On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.

High Retention Locking Outlets

PRO2 receptacles have high retention and are compatible with P-Lock type power cords.

Flexible Mounting

Includes standard button mounts along with provisions for custom mounting brackets.

Inputs
Input Voltage (V)

208

Frequency

50/60 Hz

Input Plug

208V Delta 60A IEC 60309 3P+G 9Hr

Input Current (A)

60

Input Current Rated (A)

48

Input Power Capacity (kW)

17.3

Outputs
Connector

Rating

(24) x IEC 60320/C13 North American Rating

12A @208V L-L (15A Peak)

(12) x Cx North American Rating

16A @208V L-L (20A Peak)

Specifications
Branch Circuit Protection

UL 489, CSA C22.2 No. 5 & IEC/EN60947-2 Compliant 2-pole, 20A trip circuit breakers, six (6) branch, rating: 16A, 10 kAIC Interrupt Rating

Physical

Dimensions: 70.0in tall x 2.2in wide x 2.5in deep [1778mm x 56mm x 64mm]

Environmental

Operating Environment: 32F to 140F / 0C to 60C

Communications & Security

10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

Certifications

North American:
Safety (Listed & Certified, cTUVus mark)
UL 62368-1
CSA C22.2 No. 62368-1
EMC
FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
CANICES-003, Class A

Measurement Accuracy

Input Measurement Accuracy:
Input Measurement Accuracy
LED Current = 10% at 0.1 amp (0.5 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
GUICurrent = 1% at 0.01 amp resolution (above 0.5 amp)
Voltage = 1% at 0.1 volt resolution (nominal 10%)
Active Power = 1% at 1 watt resolution
Apparent Power = 1% at 1 volt-amp resolution
Power Factor = 3% at 0.01 resolution
Crest Factor = 10% at 0.1
resolution
Energy = 1% at 0.1 kilowatt-hour resolution

Output Measurement Accuracy

GUI Current = 1% at 0.01 amp resolution (above 0.15 amp)
Voltage = 1% at 0.1 volt resolution (nominal 10%)
Active Power = 1% at 1 watt resolution
Apparent Power = 1% at 1 volt-amp resolution
Power Factor = 3% at 0.01 resolution
Crest Factor = 10% at 0.1 resolution
Energy = 1% at 1 watt-hour resolution

Branch Measurement Accuracy

Current = 3% at 0.01 amp resolution (above 0.5 amp)

Warranty
Warranty:

Manufacturer Warranty. For defective returns, Tech For Less will give you a full refund and will arrange for and pay all shipping costs.