Contact Us
Sales: 1.866.880.1230 Operating Hours Monday — Friday |
|
General | |
Model Number | PRO1 |
Product Name | Server Technology PRO1 Primary PDU |
Product Type | PDU |
Features | |
Network Monitoring | Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more. |
Star Multi-Linking | PRO1 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card. |
IP Access, Security & Communications | Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email. |
Per-Inlet Power Sensing | PIPS (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet. |
Outlet Control | On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles. |
High Temperature Rating | This product has been tested and approved for safe and reliable operation in 60 C data center environments. |
Color-Coded Options | Select from six colors to designate PDU circuits in the data center black, white, red, green, blue, and yellow. |
Hot-Swap Network Card | Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit. |
Temperature/Humidity Monitoring | Supports two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications. |
Auto-Flip Current Display | Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high density cabinets. |
Branch Circuit Protection | This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic hydraulic circuit breakers or UL 248 fuses. |
High Retention Locking Outlets | PRO1 receptacles have high retention and are compatible with P-Lock type power cords. |
Flexible Mounting | Includes standard button mounts along with provisions for custom mounting brackets. |
Inputs | |
Input Voltage (V) | 415 |
Frequency | 50/60 Hz |
Input Plug | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr |
Input Current (A) | 30 |
Input Current Rated (A) | 24 |
Input Power Capacity (kW) | 17.3 |
Input Phase | 3-Phase Wye (L-N) |
Input Cord Location | Bottom/End |
Outlet Form Factor | Conventional |
Outputs | |
Connector | Rating |
(24) x IEC 60320/C13 | North American Rating: 12A @240V L-N(15A Peak) |
Specifications | |
Branch Monitoring | Sense |
Branch Overcurrent Protection | 5 kAIC |
Branch Overcurrent Protection Type | Circuit Breaker: 1-pole |
Dual Input | No |
High Retention Outlets | Yes |
Input Current Display | Auto-Orient |
Locking Outlets | Yes |
Fast Movers | No |
Mounting | 0U Vertical |
Outlet Monitoring | None |
Branch Circuit Protection | UL 489, CSA C22.2 No. 5 & IEC/EN60947-2 Compliant 1-pole, 20A trip circuit breakers, six (6) branch, rating: 16A, 5 kAIC Interrupt Rating |
Physical | Dimensions: 69.0in tall x 1.75in wide x 3.5in deep [1753mm x 45mm x 89mm] |
Environmental | Operating Environment: 32F to 140F / 0C to 60C |
Communications & Security | 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector) |
Certifications | North American: |
Measurement Accuracy | Input Measurement Accuracy: |
Warranty | |
Warranty: | Manufacturer Warranty. For defective returns, Tech For Less will give you a full refund and will arrange for and pay all shipping costs. |